Specification ECO SMART – HEAVY DUTY AC ( R410A ) Model – Indoor Unit: SRK24CS-S6/A Model – Outdoor Unit:: SRC24CS-S6/A Tonnage: 2.0 BEE STAR RATING – 2019: 2 Star Refrigerant Control & Expansion: Dual Capillary Expansion Fixed Speed Compressor Type: Super Tropical – Return Cooled Rotary Power Source: 1 Phase, 230 V, 50 Hz Maximum Cooling Capacity* – BTU/hr: 25249 Rated Cooling Capacity at 100% Load – BTU/hr: 24908 Rated Cooling Capacity at 50% Load – BTU/hr: Not Applicable for Fixed Speed AC Maximum Cooling Capacity* – Watts: 7400 Rated Cooling Capacity at 100% Load – Watts: 7300 Rated Cooling Capacity at 50% Load – Watts: Not Applicable for Fixed Speed AC Rated Power Consumption at 100% Load – watts: 2180 Rated Power Consumption at 50% Load – watts: Not Applicable for Fixed Speed AC Rated EER / COP at 100% Load – W/w:3.35 Rated EER / COP at 50% Load – W/w: Not Applicable for Fixed Speed AC BEE Rated Indian Seasonal Energy Efficiency Ratio by ISEER: 3.35 Input Power ** ( Minimum ~ Maximum) – Watts: 1880 ~ 2180
Specification ECO SMART – HEAVY DUTY AC ( R410A ) Model – Indoor Unit: SRK24CS-S6/A Model – Outdoor Unit:: SRC24CS-S6/A Tonnage: 2.0 BEE STAR RATING – 2019: 2 Star Refrigerant Control & Expansion: Dual Capillary Expansion Fixed Speed Compressor Type: Super Tropical – Return Cooled Rotary Power Source: 1 Phase, 230 V, 50 Hz Maximum Cooling Capacity* – BTU/hr: 25249 Rated Cooling Capacity at 100% Load – BTU/hr: 24908 Rated Cooling Capacity at 50% Load – BTU/hr: Not Applicable for Fixed Speed AC Maximum Cooling Capacity* – Watts: 7400 Rated Cooling Capacity at 100% Load – Watts: 7300 Rated Cooling Capacity at 50% Load – Watts: Not Applicable for Fixed Speed AC Rated Power Consumption at 100% Load – watts: 2180 Rated Power Consumption at 50% Load – watts: Not Applicable for Fixed Speed AC Rated EER / COP at 100% Load – W/w:3.35 Rated EER / COP at 50% Load – W/w: Not Applicable for Fixed Speed AC BEE Rated Indian Seasonal Energy Efficiency Ratio by ISEER: 3.35 Input Power ** ( Minimum ~ Maximum) – Watts: 1880 ~ 2180 Current ( minimum ~ maximum ) ** – A: 8.5 ~ 9.5
Dimension (H x W x D) – Indoor Unit – mm: 339 x 1197 x 262 Dimension (H x W x D) – Outdoor Unit – mm: 640 x 850 ( + 65 ) x 290 Weight – Indoor Unit – Kgs: 17 Weight – Outdoor Unit – Kgs: 47 Air Flow ( CMH ) – Indoor Unit – m3/hr: 1300 Long Reach AirFlow Upto – Indoor Unit – Meter: 17.06 Sound Level (H/M/L) – Indoor Unit – dB: 46 / 42 / 39 Louver Swing – Indoor Unit: 2D Special Filter – Indoor Unit: Anti – Bacterial Blower Fan – Indoor Unit: Anti – Micro Bial DC Fan Motor Speed – Indoor Unit: Auto / Powerful / High / Med / Low Refrigerant Injection in Coil – Indoor Unit: 5 Point – Multi Port Refrigerant Piping – Liquid Line – mm: 6.35 ( 1/4″ ) Refrigerant Piping – Gas Line – mm: 15.88 ( 5/8″ ) Main Power Supply to – Indoor Unit: 2.5 mm2 x 3 cores ( including earthing ) Connecting wiring between B/w IDU &: 2.5 mm2 x 4 cores ( including earthing ) Area Coverage *** – Sq. Meter: 18.58 ~ 27.87
Return and Replacement is subject to the Return Policy.
For any other queries, do reach out to Jantacart Care at : [email protected].
Light shipment are shipped by Delhivery Express and Expacted Delivery Time 3 Day from the date of order processing, Delay only happed due to connectivity issue.
Medium shipment are shipped by DELHIVERY/GATI/REVIGO and expacted delivery time is 5 days delay will be happens due to pickup and Shipment connectivity issues from the date of order processing.
Large shipment are shipped by DELHIVERY/GATI/REVIGO and expacted delivery time is 7-15 days depends upon customer delivery pincode weather its in direct location or in ESS(Extra Service Location) delay also happens due to pickup and Shipment connectivity issues from the date of order processing
All products inventory are managed by company Authorize distributor after their confirmation order will update and dispatche.
If Delivery Pincode Is In ESS Extra Service location then their will be too much delay in the delivery, It's ESS delivery charges will be applicable as per logistics.
Given below is a diagram that explains the payment flow for Cardless EMI:
The payment flow for a customer using cardless EMI at Standard Checkout is described below:
Customers enter the required details on the Checkout page and select EMI.
Customers select the preferred cardless EMI service provider.
If the amount entered in the Checkout is eligible for EMI, customers are sent an OTP on their registered mobile numbers to authenticate their account with the selected cardless EMI service provider.
If the entered mobile number is invalid, an error message is displayed that the user does not have an account with the service provider.
After the successful verification, customers select EMI plan of their choice and complete the transaction.
You will receive the entire payment amount from the cardless EMI service provider. Based on the terms and conditions, the customer pays the total payment amount with additional interest (if any) as EMIs to the provider.