Key Feature Mud resist structure (dust-resistant, mud-resistant) Quad sensor (Thermometer, Altimeter/Barometer, Digital Compass, Step Counter) Super Illuminator auto double LED light for face and digital display illumination Size of case / Total weight Size of case : 55.4×53.1×19.3mm Total weight : 92g
Double LED light LED light for the face (Auto LED light, Super illuminator, selectable illumination duration (1.5 seconds or 3 seconds), afterglow)
LED backlight for the digital display (Auto LED light, Super illuminator, selectable illumination duration (1.5 seconds or 3 seconds), afterglow)
Mobile link (Wireless linking using Bluetooth®)
Digital compass Measures and displays direction as one of 16 points
Measuring range: 0 to 359°
Measuring unit: 1°
60 seconds continuous measurement
Hand indication of north
Magnetic declination correction
Direction calibration (2-point calibration, figure eight calibration, auto calibration)
Altimeter Measuring range: –700 to 10,000 m (–2,300 to 32,800 ft.)
Measuring unit: 1 m (5 ft.)
Hand indication graph of altitude differential
Manual memory measurements (up to 14 records, each including altitude, date, time)
Auto log data (High/low altitudes, cumulative ascent and descent)
Others: Relative altitude readings (±100 m /±1000 m), selectable measurement interval: 5 seconds or 2 minutes (1 second for first 3 minutes only)
*Changeover between meters (m) and feet (ft)
Barometer Measuring range: 260 to 1,100 hPa (7.65 to 32.45 inHg)
Measuring unit: 1 hPa (0.05 inHg)
Hand indication of pressure differential (±10 hPa)
Atmospheric pressure tendency graph (last 20 hours or last 56 hours)
Barometric pressure tendency information alarm (beep and arrow indicates significant changes in pressure)
The atmospheric pressure tendency graph can show the last 20 minutes or last 56 minutes of measurements. The hand indication of pressure differential shows values in units of ±1 hPa.
*Changeover between hPa and inHg
Thermometer Measuring range: –10 to 60°C (14 to 140°F)
Measuring unit: 0.1°C (0.2°F)
*Changeover between Celsius (°C) and Fahrenheit (°F)
Step count using a 3-axis acceleration sensor: 0 to 999,999 step count display range Power Saving: Auto sensor sleep state entry after fixed period of non-activity
World time 38 time zones (38 cities + coordinated universal time), daylight saving on/off, Home city/World time city swapping
Sunrise, sunset time display Sunrise time and sunset time for specific date
1/100-second stopwatch 00'00''00~59'59''99 (for the first 60 minutes)
1:00'00~23:59'59 (after 60 minutes)
Measuring unit:
1/100 second (for the first 60 minutes)
1 second (after 60 minutes)
Measuring modes: Elapsed time, split time, 1st-2nd place times
Countdown timer Measuring unit: 1 second
Countdown range: 24 hours
Countdown start time setting range: 1 second to 24 hours (1-minute increments and 1-hour increments)
Return and Replacement is subject to the Return Policy.
For any other queries, do reach out to Jantacart Care at : [email protected].
Light shipment are shipped by Delhivery Express and Expacted Delivery Time 3 Day from the date of order processing, Delay only happed due to connectivity issue.
Medium shipment are shipped by DELHIVERY/GATI/REVIGO and expacted delivery time is 5 days delay will be happens due to pickup and Shipment connectivity issues from the date of order processing.
Large shipment are shipped by DELHIVERY/GATI/REVIGO and expacted delivery time is 7-15 days depends upon customer delivery pincode weather its in direct location or in ESS(Extra Service Location) delay also happens due to pickup and Shipment connectivity issues from the date of order processing
All products inventory are managed by company Authorize distributor after their confirmation order will update and dispatche.
If Delivery Pincode Is In ESS Extra Service location then their will be too much delay in the delivery, It's ESS delivery charges will be applicable as per logistics.
Given below is a diagram that explains the payment flow for Cardless EMI:
The payment flow for a customer using cardless EMI at Standard Checkout is described below:
Customers enter the required details on the Checkout page and select EMI.
Customers select the preferred cardless EMI service provider.
If the amount entered in the Checkout is eligible for EMI, customers are sent an OTP on their registered mobile numbers to authenticate their account with the selected cardless EMI service provider.
If the entered mobile number is invalid, an error message is displayed that the user does not have an account with the service provider.
After the successful verification, customers select EMI plan of their choice and complete the transaction.
You will receive the entire payment amount from the cardless EMI service provider. Based on the terms and conditions, the customer pays the total payment amount with additional interest (if any) as EMIs to the provider.